Subject: Vitalink TC-NCC test with Peppers Stainless Steel Cable Gland at 2000°F for 30 minutes RSCC tested Peppers Stainless Steel Cable Gland type CR-U Compound filled with 4/C 14 AWG Vitalink TC-NCC. The cable maintained circuit integrity with 15A load 3 phase in a “modified IEC 60331” fire test for 30 minutes at 2000°F (also called Chevron test). The fourth leg was connected to ground, the cable was mounted on steel basket tray. Peppers CR-X was also tested and is approved for use with Vitalink TC/NCC. |